Open Layout in a chart view’s toolbar and set the fields below. Cycle time and Cycle time ended are a duration measure’s fields, listed under History.

  1. Set Chart type to Bar and the Y-axis to Count (items).
  2. Set the X-axis to Cycle time.
  1. Set Chart type to Bar and the Y-axis to Count (items).
  2. Set the X-axis to Cycle time ended.
  3. Set Group dates by to Week.
  1. Set Chart type to Scatter.
  2. Set the X-axis to Cycle time ended and the Y-axis to Cycle time.
  3. To show only recent work, filter the view on Cycle time ended.
  1. Filter the view to items that are not finished.
  2. Set Chart type to Scatter.
  3. Set the X-axis to Status and the Y-axis to Time in Status.

A reopened item leaves the throughput count until it is finished again, because its measure has no end until then. See How duration measures work.